How Microsoft measures datacenter water and energy use to improve Azure Cloud sustainability

April 22, 2022 by cbn Leave a Comment

One of the biggest topics of discussion at COP26, the global climate conference held in November 2021, was how a lack of reliable and consistent measurement hampers progress on the path to Net Zero. I have been reflecting on this issue and, on this Earth Day, I would like to provide an update on how we are measuring energy and water use at our datacenters to improve sustainability across the Azure Cloud.

Today, we’re sharing an important update on how Microsoft, and our datacenters, are helping to solve our part of this measurement challenge.

While the environmental goals are similar, each industry has unique challenges in measuring its carbon emissions to build its sustainability strategy. It’s one of the key reasons we, together with ClimateWorks Foundation and 20 other leading organizations, launched the Carbon Call. It’s also why we developed Microsoft Cloud for Sustainability, an Azure-based platform that allows organizations to combine disparate data sources into one place and help provide insights into how to improve their sustainability approaches.

You’ve told us just how important measuring energy and water consumption from our datacenters is in taking sustainability into account for commercial decisions. Below you will see, for the first time, our datacenter PUE (Power Usage Effectiveness) and WUE (Water Usage Effectiveness) metrics. To address these capabilities, we set design goals—our theoretical estimates of the most efficient we can operate our datacenters—and ensure we have measurements of our actual efficiencies. These targets can vary between datacenter generations and usage; for instance, newer datacenter generations as well as datacenters operating at peak utilization are more efficient. We track these statistics at a global level and by our operating geographies—Americas, Asia Pacific, and EMEA (Europe, Middle East, Africa).

Understanding Power Usage Effectiveness (PUE)

PUE is an industry metric that measures how efficiently a datacenter consumes and uses the energy that powers the datacenter, including the operation of systems like powering, cooling, and operating the servers, data networks and lights. The closer the PUE number is to “1,” the more efficient the use of energy.

While local environment and infrastructure can affect how PUE is calculated, there are also slight variations across providers. Here’s the simplest way to think about PUE.

Microsoft datacenter power usage effectiveness (P U E) equals (total energy needed for facility) divided by (total energy used for computing)

We design and build our datacenters toward the optimum PUE figure. We can also predict, with a high degree of accuracy, that optimum PUE figure. As we constantly innovate, we factor these changes into our datacenter designs to get as close to “1” as feasible. Our newest generation of datacenters have a design PUE of 1.12 and, with each new generation, we strive to become even more efficient. In the chart below, the blue bars show our estimated, or designed, PUE figures, while the grey bars indicate our actual PUE figures. As you can see, in Asia Pacific our actual PUE is higher; that’s due in part to higher ambient temperatures in the region which necessitates additional cooling.

In almost every region, our actual operating PUE is more efficient than our designs.

Comparison of P U E design goal with actual P U E across Americas, Asia Pacific, Europe/Middle East/Africa, and Global

Understanding Water Usage Effectiveness (WUE)

Water Usage Effectiveness (WUE) is another key metric relating to the efficient and sustainable operations of our datacenters and is a crucial aspect as we work towards our commitment to be water positive by 2030.

WUE is calculated by dividing the number of liters of water used for humidification and cooling by the total annual amount of power (measured in kWh) needed to operate our datacenter IT equipment.

Microsoft datacenter water usage effectiveness (W U E) equals (annual liters of water used for humidification and cooling) divided by (total annual kilowatt hour used to power IT equipment)

Like PUE, there are variables that can impact WUE—many of which relate to the location of the datacenter. Humid locations often have more atmospheric water, while arid locations have very little. Datacenters in colder parts of the world, like Sweden and Finland operate in naturally cooler environments so require less water for cooling. Our datacenter designs minimize water use. The chart below shows (in blue) our estimated or designed WUE figure, and in grey, our actual WUE figure. Again, Asia Pacific is higher due to higher ambient temperatures and as a result the need in some places for water-cooled chillers.

Comparison of W U E design goal with actual W U E in (Liters over kilowatt hours) across Americas, Asia Pacific, Europe/Middle East/Africa, and Global

We continue to integrate our standards in water reduction technologies such as those in our Phoenix, Arizona datacenter where we use direct outside air most of the year to cool servers. We otherwise cool through direct evaporation that requires a fraction of the water compared to other, conventional water-based cooling systems such as water-cooled chillers.

Furthermore, by powering our datacenter with power from the Sun Streams 2 Solar Project owned by local partner, Longroad Energy, we’re displacing the water needed in the traditional electricity generation process and expect to save 356 million liters of water annually.

Scope 3 and supply chain

As we shared in March with our annual sustainability report, we made good progress on a number of our goals. Across the company’s operations, we saw an overall reduction in our Scope 1 and Scope 2 emissions of about 17 percent year over year, through our purchasing of renewable energy. At the same time, we also saw a rise in our Scope 3 emissions, which increased about 23 percent year over year.

We know that Scope 3 emissions (representing the total emissions across a company’s entire value chain) are the most difficult to control and reduce, because we can often only influence change. We know this is a long-term effort and this year we have increased our focus on operational discipline that is rooted in reliable data. We’ve also been working with partners across the industry, including Infrastructure Masons on carbon transparency within the datacenter supply chain, and will have exciting news to share at the Datacloud Global Congress on April 25 to 27.

Learn more

We know just how crucial data transparency and consistency are in helping our customers make the correct choices for their business, and hope that today’s announcement on our PUE and WUE data will be an important step forward in informing decisions about their sustainability strategies.

To learn more about our datacenter operations and commitments in action today, you can visit:

  • Microsoft sustainability
  • Azure sustainability
  • Microsoft Azure's global infrastructure
  • Take a virtual tour of Microsoft’s datacenters
Share on FacebookShare on TwitterShare on Google+Share on LinkedinShare on Pinterest

Filed Under: CLOUD

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Archives

  • September 2025
  • August 2025
  • July 2025
  • June 2025
  • May 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024
  • October 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
  • May 2023
  • April 2023
  • March 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • September 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022
  • March 2022
  • February 2022
  • January 2022
  • December 2021
  • November 2021
  • October 2021
  • September 2021
  • August 2021
  • May 2021
  • April 2021
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • March 2020
  • February 2020
  • January 2020
  • December 2019
  • November 2019
  • October 2019
  • September 2019
  • August 2019
  • July 2019
  • June 2019
  • May 2019
  • April 2019
  • March 2019
  • February 2019
  • January 2019
  • December 2018
  • November 2018
  • October 2018
  • September 2018
  • August 2018
  • July 2018
  • June 2018
  • May 2018
  • April 2018
  • March 2018
  • February 2018
  • January 2018
  • December 2017
  • November 2017
  • October 2017
  • September 2017
  • August 2017
  • July 2017
  • May 2017
  • April 2017
  • March 2017
  • February 2017
  • January 2017
  • March 2016

Recent Posts

  • How Azure Cobalt 100 VMs are powering real-world solutions, delivering performance and efficiency results
  • FabCon Vienna: Build data-rich agents on an enterprise-ready foundation
  • Agent Factory: Connecting agents, apps, and data with new open standards like MCP and A2A
  • Azure mandatory multifactor authentication: Phase 2 starting in October 2025
  • Microsoft Cost Management updates—July & August 2025

Recent Comments

    Categories

    • Accounting
    • Accounting Software
    • BlockChain
    • Bookkeeping
    • CLOUD
    • Data Center
    • Financial Planning
    • IOT
    • Machine Learning & AI
    • SECURITY
    • Uncategorized
    • US Taxation

    Categories

    • Accounting (145)
    • Accounting Software (27)
    • BlockChain (18)
    • Bookkeeping (205)
    • CLOUD (1,322)
    • Data Center (214)
    • Financial Planning (345)
    • IOT (260)
    • Machine Learning & AI (41)
    • SECURITY (620)
    • Uncategorized (1,284)
    • US Taxation (17)

    Subscribe Our Newsletter

     Subscribing I accept the privacy rules of this site

    Copyright © 2025 · News Pro Theme on Genesis Framework · WordPress · Log in